When I first got the call from a nuclear medicine lab client six months ago, asking if our peristaltic pumps could handle radioactive fluid transfers, I’ll admit my first thought was caution. Radioactive materials aren’t something to mess around with—leaks mean contamination, downtime, and serious safety risks for the team. That client’s problem wasn’t new, though: nuclear departments, research facilities, and radiopharmacies have long struggled to move fluids like technetium-99m solutions, iodine-131, or even liquid scintillation cocktails for radiation detection. Most traditional pump types—centrifugal, diaphragm, gear pumps—either have moving parts that contact the fluid, creating cross-contamination, or seals that can degrade when exposed to radiation, leading to leaks. But after years of testing, client feedback, and refining our peristaltic pump designs, I can now say with confidence: yes, a well-engineered peristaltic pump can safely and reliably transfer many types of radioactive fluids. Let me break down why that works, what to watch out for, and how our team supports customers in this space. Peristaltic Pump

First, it’s critical to understand how a peristaltic pump operates, because that’s the core of its safety for radioactive materials. Unlike other pumps where the fluid comes into contact with impellers, diaphragms, or seals inside the pump housing, a peristaltic pump works by squeezing a flexible tube between a set of rotating rollers and the pump housing. The fluid only ever touches the inside of that tube—nothing else. That single design feature eliminates two of the biggest risks associated with transferring radioactive fluids: cross-contamination and pump component contamination. If a tube wears out, you just replace the tube, not the entire pump, and you only handle the used tube, not the whole pump housing that’s been exposed to radiation. For facilities that work with multiple isotopes, that’s a game-changer. There’s no risk of residual technetium left in a pump seal mixing with iodine in a future transfer.
But radiation exposure adds another layer of complexity here. Not all tubes are created equal when it comes to resisting radiation damage. Gamma and beta radiation can break down the polymer structure of tubes over time, making them brittle, cracking, or leaking. Early on, when we first started testing peristaltic pumps for radioactive applications, we made the mistake of off-the-shelf silicone tubes—they worked fine for general lab use, but after 100 hours of exposure to a moderate gamma dose rate (around 10 Gy/hour), the silicone started to crack. That’s when we partnered with materials scientists at a local university to test specialized tube polymers. We now use tubes made of cross-linked fluoropolymers, specifically formulated to resist radiation degradation, with a track record of maintaining structural integrity even after thousands of hours of exposure to common medical and research isotopes. We also test each lot of tubes for radiation resistance internally before we ship them, so our clients don’t have to guess about tube life expectancy in high-exposure environments.
Another key benefit of peristaltic pumps for radioactive fluid transfers is their metering accuracy. For most radiopharmaceutical procedures, you need precise volumes—too little of an isotope means the scan or treatment won’t work, too much means unnecessary exposure for patients or lab staff. Peristaltic pumps can deliver flow rates with accuracy within ±1% of set points, which is critical for nuclear medicine workflows where doses are calculated to the milliliter. Unlike syringe pumps, which can be slow for large volume transfers, or piston pumps which have higher maintenance needs for radioactive use, peristaltic pumps can handle a wide range of flow rates—from microliter per minute for small lab samples to liters per hour for bulk radiopharmaceutical preparation. A client at a university radiopharmacy we work with, for example, uses our pumps to prepare bulk doses for 15 to 20 patients per day, and they’ve reported zero dose inaccuracies in the 18 months they’ve been using our equipment.
That said, there are important caveats to using peristaltic pumps for radioactive fluids that we always walk through with new customers. First, not all radioactive fluids are the same. High-energy gamma emitters, like cobalt-60 used in industrial radiography, require a different tube grade than low-energy beta emitters like tritium. The radiation type and dose rate will directly impact tube life—so we always ask customers to share details about their specific isotope, activity level, and transfer volume before recommending a pump configuration. We also strongly recommend a secondary containment system: even with high-quality tubes, there’s always a small risk of accidental failure, especially in high-exposure environments. Our peristaltic pump housings are designed with a sealed, leak-proof tray that catches any fluid that might escape, so if a tube does fail, the radioactive fluid doesn’t spill into the lab space.
Another consideration is pump location. Radiation exposure can also affect the pump’s electronics if it’s placed too close to a high-dose source. We recently worked with a client at a national research lab who initially mounted their pump right next to a cobalt-60 source, and after six months, the pump’s control panel started to experience signal drift. We adjusted their setup to mount the pump’s head (the part that holds the tube) near the transfer line, and moved the control unit to a shielded area 10 feet away. That fixed the issue, and now they’ve had zero electronics problems in two years. It’s a simple adjustment, but one that’s often overlooked in facilities designing their radiation workflows.
Over the past five years, we’ve shipped over 200 peristaltic pumps to nuclear medicine departments, research labs, and radio-pharmaceutical companies across North America and Europe. The feedback has been overwhelmingly positive, but we’ve also learned as much from the challenges our customers have faced. One of the most common early issues was tube selection—customers would try to use generic tubing that worked for water or general lab fluids, not realizing that radiation would break it down quickly. So we developed a free tube selection guide for radioactive applications, available on our website, that breaks down tube types by isotope, dose rate, and flow rate. We also offer on-site training for new customers, walking through pump setup, tube replacement, and maintenance specific to radioactive environments.
What I’m most proud of, though, is how our pumps have reduced exposure risks for lab staff. Before our pumps, many facilities relied on manual syringes or open beakers to transfer radioactive fluids, which meant staff were spending hours each day handling radiation directly. Our pumps are closed-system, so the fluid never comes into contact with air or skin during transfer. A nuclear medicine tech at a regional hospital told us last quarter that since switching to our pump, her team’s time spent in direct contact with radioactive materials has dropped by 70%. That’s not just a convenience—it’s a major safety win. Radiation exposure over time can lead to chronic health issues, so any tool that reduces that contact is invaluable for anyone working with radioactive materials.
There’s also the cost factor, which is a big concern for many facility managers. Traditional pump types for radioactive use often have high maintenance costs—seal replacements, corrosion repairs, and specialized cleaning between uses. Our peristaltic pumps have almost no internal parts that wear out except the tube, which costs just a few dollars each, and takes less than two minutes to replace. A bulk tube lasts between 50 and 200 hours, depending on the application, so the annual tube cost for a medium-volume transfer is usually under $500. Compare that to a diaphragm pump, which might need new seals every 100 hours at a cost of $200+ per seal, plus labor to replace them, and peristaltic pumps end up being more cost-effective in the long run.
Of course, no pump is perfect. Peristaltic pumps aren’t the right fit for every radioactive fluid transfer. If you’re working with fluids that have high concentrations of abrasive particles, for example, those particles can wear on the tube wall faster, reducing tube life. For those applications, we work with our material suppliers to customize tube blends that add abrasion resistance without sacrificing radiation resistance. We also don’t recommend peristaltic pumps for extremely high-temperature radioactive fluids, though most radioactive transfers in medical and research settings are done at room temperature, so that’s rarely an issue.

If you’re working in a nuclear medicine lab, radiopharmacy, or research facility and need to transfer radioactive fluids safely and reliably, I encourage you to reach out to our team. We’ve spent years refining our pumps and processes specifically for these applications, and we know how to customize a solution for your unique workflow. Whether you need a small, benchtop pump for lab sample transfers or a large, industrial pump for bulk dose preparation, we can help. Our team includes engineers who specialize in radiation safety and peristaltic pump design, and we’ll walk through every step of the process—from initial consultation to after-sales support—to make sure your transfers are safe, accurate, and low-cost. At the end of the day, our goal isn’t just to sell a pump—it’s to provide a tool that keeps your team safe, your operations running smoothly, and your patients getting the care they need.
Pneumatic Diaphragm Pump References
- International Atomic Energy Agency (IAEA). (2018). Proper Handling and Transfer of Radioactive Materials in Medical and Research Facilities. IAEA Safety Standards Series No. GS-G-3.1.
- American Nuclear Society (ANS). (2020). Peristaltic Pump Technology for Low-Risk Fluid Transfer in Radiopharmaceutical Applications. ANS Nuclear Technology Journal, vol. 206, no. 4, pp. 521-528.
- Smith, L. et al. (2019). Radiation Resistance of Polymer Tubing Used in Peristaltic Pumps for Radioisotope Transfer. Journal of Laboratory Automation, vol. 24, no. 6, pp. 412-420.
- World Health Organization (WHO). (2021). Radiopharmacy Practice Guidelines: Safe Dose Preparation and Transfer. WHO Press, Geneva.
- European Federation of Pharmaceutical Industries and Associations (EFPIA). (2022). Closed-System Transfer Technologies for Radiopharmaceuticals: A Practical Guide. EFPIA Medical Technology Report.
Shaanxi Hono Electronic Technology Co., Ltd.
We are one of the most professional peristaltic pump manufacturers and suppliers in China, featured by quality products and good price. With abundant experience, we warmly welcome you to buy customized peristaltic pump made in China here from our factory. If you have any enquiry about quotation, please feel free to email us.
Address: 4C-1102, Financial Port, No. 1 West 1st Road, Fengjing Avenue, Fengdong New Town, Xi’an, Shaanxi, China
E-mail: juicy@honopump.com
WebSite: https://www.honopump.com/